Back to file

Schema

Lock Gate Lines (USACE IENC) / Lock Gate Lines (USACE IENC) / v1.0.0

View metadata

Schema from lock-gate-lines-usace-ienc-2.parquet, gcp-portolan-published, v1.0.0.

The USACE IENCs coverage area consists of 7,260 miles across 21 rivers primarily located in the Central United States. IENCs apply to inland waterways that are maintained for navigation by USACE for shallow-draft vessels (e.g., maintained at a depth of 9-14 feet, dependent upon the waterway project authorization). Generally, IENCs are produced for those commercially navigable waterways which the National Oceanic and Atmospheric Administration (NOAA) does not produce Electronic Navigational Charts (ENCs). However, Special Purpose IENCs may be produced in agreement with NOAA. IENC POC: IENC_POC@usace.army.mil

Columns
13 columns
Features
299
Geometry
LineString
ColumnTypeNullableNullsUniqueDescriptionExamples / Values
geometrygeometryNo0——
Range: —Length: —
Examples: —
Values: —
OBJECTIDintegerNo0——
Range: 1 to 299Length: —
Examples: 207, 189, 13, 220, 238
Values: —
Category_ostringNo0——
Range: —Length: 18
Examples: Lock Gate, Lock Gate, Lock Gate, Lock Gate, Lock Gate
Values: Flood Barrage Gate, Lock Gate
HorizontalstringNo0——
Range: —Length: 7
Examples: 33.5, 33.5, Unknown, 33.5, 33.5
Values: 17.1, 18.3, 22.4, 22.5, 22.9, 24.4, 25.6, 26.6, 32.5, 33.5, 33.52, 33.53, 7.92, Unknown
Vertical_CstringYes286——
Range: —Length: 7
Examples: Unknown, Unknown, Unknown, Unknown, Unknown
Values: Unknown
Object_NamstringYes290——
Range: —Length: 41
Examples: Lock 25 Main Lock Downstream Miter Gate, Mel Price Aux Lock Upstream Miter Gate, Jerry F. Costello Upstream Miter Gate, Mel Price Main Lock Downstream Miter Gate, Lock 25 Aux Miter Gate
Values: Jerry F. Costello Downstream Miter Gate, Jerry F. Costello Upstream Miter Gate, Lock 25 Aux Miter Gate, Lock 25 Main Lock Downstream Miter Gate, Lock 25 Main Lock Upstream Miter Gate, Mel Price Aux Lock Downtream Miter Gate, Mel Price Aux Lock Upstream Miter Gate, Mel Price Main Lock Downstream Miter Gate, Mel Price Main Lock Upstream Lift Gate
InformatiostringYes288——
Range: —Length: 96
Examples: Auxillary Lock Chamber, Auxilliary Gate, Lift gate, Harbor closure flood gate. Gates close with river stages over 18' on the Dubuque RR Bridge gage., Main Lock Chamber
Values: Auxillary Lock Chamber, Auxilliary Gate, Gate is located within main lock chamber., Harbor closure flood gate. Gates close with river stages over 18' on the Dubuque RR Bridge gage., Lift gate, Lockage Size = 84ft x 705ft, Main Lock Chamber
Scale_MiniintegerNo0——
Range: 22000 to 90000Length: —
Examples: 22000, 22000, 22000, 22000, 22000
Values: —
Source_DatstringNo0——
Range: —Length: 8
Examples: 20200716, 20200716, 20130701, 19991201, 20140910
Values: —
Source_IndstringNo0——
Range: —Length: 88
Examples: US,U3,SURVY,SAM_Field_Survey,IENC_20_050, US,U3,SURVY,SAM_Field_Survey,IENC_20_050, US,U3,SURVY,SWL_Field_Survey,IENC_13_033, US,U3,graph,St_Louis_SDS_1999, US,U3,SURVY,MVR_Field_Survey,IENC_14_061
Values: —
Source_D_1stringNo0——
Range: —Length: 12
Examples: U37TT385.000, U37TT218.000, U37AR246.000, U37UM218.000, U37UM432.000
Values: —
SHAPE_LengfloatNo0——
Range: 0.000040521599186 to 0.00046864274995Length: —
Examples: 0.000407944398657, 0.000406391611348, 0.000347739478856, 0.000332604878673, 0.000369295647617
Values: —
idintegerNo0——
Range: 1 to 299Length: —
Examples: 207, 189, 13, 220, 238
Values: —
Quality checks: Passed
Invalid geometry count: 0
Columns hash: c75981c9f6bff0028229637f9dcabd2dc19d17e0526d376a6df40f239c0c26b8